Forced Connection To The Control Port (Pseudo Local Mode); Ok/Differ Management Mode; Standard Mode - Safran CORTEX Series User Manual

High data rate receiver
Table of Contents

Advertisement

 Enter the Control password. Default setting at delivery: no password. Control pushbuttons are
changed to:
 Click on
 Change the parameter setting and click on
1. opens a connection to the Control port,
2. transmits the configuration commands to the Signal Processing Software,
3. closes the connection to the Control port and returns to the monitoring mode. The
pushbutton is changed to
To cancel the modifications, click on
To reconfigure the CORTEX in a multi-operator environment, read section 4.3.6.4 .
4.3.6.3

Forced Connection to the Control Port (Pseudo Local Mode)

After entering the Control password, the CORTEX can be set to a pseudo local mode by keeping open
a TCP-IP connection to the Control port: reconfiguration of the unit by remote Control Clients remains
impossible until the connection is released by the local Operator or a Reset Control port command is
received on the Reset port.
To open a connection to the Control port, click on EXECUTE  OPEN CONTROL PORT. To close the
connection to the Control port, click on EXECUTE  CLOSE CONTROL PORT.
4.3.6.4

OK/DIFFER Management Mode

The OK/DIFFER management mode is used to customize the configuration process. Three modes are
proposed: STANDARD, PROTECTED and AUTOMATIC. Mode selection is from menu
PREFERENCES.
4.3.6.4.1

Standard Mode

When the CONFIG button is pressed, the status part of the GUI keeps on being refreshed in real time
but the parameter part shows the contents of the active MCS Table (and not the parameter values
returned in the monitoring tables). At this point, it should be noted that if the MCS control status is set
to
,
clicking on APPLY will reconfigure the equipment from the contents of the MCS
Table !
New parameter values entered by the Operator are stored in the MCS Table and when the APPLY
button is pressed, the CORTEX is re-configured from the MCS Table and the MCS control status
indicates
.
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
. The pushbutton is changed to
instead of
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100782
Is.Rev
3.5
Date:
June 1, 2021
.
. The MCS:
.
or close the window.
Safran Data Systems
.
Page 222