Output Data Definition And Timing; Timing For All Output Types - Safran CORTEX Series User Manual

High data rate receiver
Table of Contents

Advertisement

2.2.3

Output Data Definition and Timing

2.2.3.1

Timing for all output types

CLK+ *
OUTx +/- **
For I/Q merged output, RS CADU output and LDPC CADU output:
t
= 1/2BR - 500 ps
s
t
= 1/2BR - 500 ps
h
For normal I and Q outputs:
t
= 1/BR - 500 ps
s
t
= 1/BR - 500 ps
h
* Clock polarity: Normal Output Clock
** Except when OUT3 = CLK
Remark: For data output after specific decoding process (example: TCM + RS-DVB, punctured
Viterbi), "holes" inside the output data and clock signals can be present. These "holes" are due to the
delayed check symbols and / or synchronization words. Nevertheless it has to be considered that for
each data corresponds an edge of the clock.
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
1 / Bit Rate
t
t
s
h
DATA
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100782
Is.Rev
3.5
Date:
June 1, 2021
Safran Data Systems
.
Page 73