 STEP 1: When the Monitoring & Control Software (MCS) is started, it opens the default MCS
Document (program argument) c:\Program Files\In-snec\crtxMcx\cortex-nt.mcs on the disk and
makes a copy in RAM (MCS Table). If the default MCS Document is not found the following
warning message is displayed:
 STEP 2: The MCS connects to the Monitoring port of the CORTEX and starts monitoring the
machine. If the MCS fails to open the connection, the MCS Login window indicates
Disconnected and a warning message is displayed.
 STEP 3: Once the connection to the CORTEX has been established, the configuration
parameters, the status and alarms received from the connected machine are refreshed in real
time on the GUI. Configuration commands entered at the GUI are executed and the MCS Table
refreshed accordingly.
 STEP 4: The MCS permanently compares the configuration parameters from the MCS Table to
the ones displayed on the GUI.
 STEP 5: If the GUI strictly reflects the contents of the MCS Table, the MCS control status at
the bottom of the Top Level window displays:
Else (the CORTEX has been reconfigured by a remote M&C client or the MCS document has
not been saved properly prior shutting down the machine) the MCS control status is changed
to:
 Click on icon
 Click on icon
(CTX table).
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
to reconfigure the CORTEX from the MCS Table, or
to update the MCS Table from the configuration parameters on the GUI