The number of the selected file appears inside the "Selected" box. The status "Last Conf" is equivalent
to the OK/Differ status of GUI.
4.3.11
MCS File System Architecture
IN-SNEC MCS software can be found in the following directories. Do not move or modify these
directories:
ACCESS PATH
C:\Program Files\In-snec
Or
D:\ZDS\Data\HDR
4.3.12
MCS System Parameters in Registry
MCS system parameters are high-level parameters in the registry. Changing them requires restarting
the CORTEX MCS application software:
4.3.12.1
Monitoring
4.3.12.1.1
Monitoring Rate
To change the time interval between two consecutive monitoring cycles by the MCS software:
Registry path:
Keyword:
Setting:
Example: for a monitoring request every four seconds, enter FA0 (in hexadecimal) or 4000 (in decimal).
Minimum value: 1F4
H
4.3.12.2
MCS Auto-Connect
The following registry keys enables to force the MCS to regularly attempt to reconnect to the monitoring
port of the CORTEX. The auto-connect mode is particularly useful on multi-menu CORTEX.
4.3.12.2.1
Auto Connect ON/OFF
Registry path:
Keyword:
Setting:
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
\CrtxMcs
HKEY_LOCAL_MACHINE / SOFTWARE\In-Snec\CrtxMcs\Tcp
Monitoring
500D. Default: 500. Expressed in ms
= 500
(monitor the equipment twice per second).
D
HKEY_LOCAL_MACHINE / SOFTWARE\In-Snec\CrtxMcs\Tcp
AutoReconnect
0: auto-connect mode disabled. 1: auto-connect mode enabled
Ref.
Is.Rev
Date:
DESCRIPTION
Root directory
Upgrade.txt: list of s/w packages (ID + version)
Monitoring & Control Software
Graphical User Interface
DefaultConfig
DefaultConfig_ref
UserConfig
Safran Data Systems
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
DTU 100782
3.5
June 1, 2021
MCS files
MCS files (read only
reference files)
MCS files (read only
reference files)
.
Page 227