Monitoring; Upper Banner; Other Status & Alarms - Safran CORTEX Series User Manual

High data rate receiver
Table of Contents

Advertisement

4.5.4.5.2

Monitoring

4.5.4.5.2.1

Upper Banner

See section 4.5.4.1.2.1
4.5.4.5.2.2
Other Status & Alarms
 For TCM configuration:
BER
TCM DECODER
 For single Viterbi configuration:
BER
VITERBI DECODER
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
 5/6(conv.1) 5/6 Viterbi (convention 1)
 5/6(conv.2) 5/6 Viterbi (convention 2)
 6/7
6/7 Viterbi
 7/8 (conv.1) 7/8 Viterbi (convention 1)
 7/8 (conv.2) 7/8 Viterbi (convention 2)
 1/4 Esrin
1/4 Viterbi (ESA / ESRIN type)
.
TCM Bit Error Rate (must be 0 if no error detected). Important: the BER is
analyzed at the bit synchronizer output (before TCM decoding)
TCM decoder status:
 Locked
 Unlocked
 Disabled
Viterbi Bit Error Rate (must be 0 if no error detected). Important: the BER is
analyzed at the bit synchronizer output (before Viterbi decoding)
Viterbi decoder status:
 Locked
 Unlocked
 Disabled
It cannot be duplicated or distributed without expressed written consent.