Safran CORTEX Series User Manual page 245

High data rate receiver
Table of Contents

Advertisement

MONITORING FLOW ID
LOGGING FLOW ID
CABLE
COMPENSATION
REFERENCE
FREQUENCY
CONFIGURATION
MENU
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
Identification of the monitoring data flow. This value is reported in all TCP-IP
messages transmitted over the Monitoring port (MON). Enter any hexadecimal
value from 0 to FFFFFFF. The Flow ID value in the incoming monitoring
requests must match the programmed value.
Identification of the logging flow. This value is reported in all TCP-IP messages
transmitted over the Logging port (LOG). Enter any hexadecimal value from 0
to FFFFFFFF.
Determines the evaluated loss (in dB) due to cables among the propagating path.
This value is reported in the calculation of the compensating filter's coefficients.
Enter any value from 0 to 12 (Option)
Selection of the frequency reference internal or external.
The easier way to configure the unit is to load the selected MCS file (refer to
paragraph 4.3). As soon as the MCS file is loaded, the unit can automatically
load the firmware corresponding to this MCS file.
The Configuration Window allows the User to force the selection of a basic
menu and gives also indications about the status of the selection an loading
operations.
In manual mode (Mode: On Request or On Accept) the operator can input in the
field: Menu Nbr the numbers of a basic menus (Demodulator, test Modulator
and the optional Extension board when present). If the operation mode is set to
On Accept, the loading will be effective only after having clicked the button
Accept Request Menu
In automatic mode (Automatic or Automatic with Accept) the basic menu
corresponding to the current configuration is selected automatically and its
number is displayed in the Recommended status field. If the operational mode is
set to Automatic with Accept, the loading will be effective after having clicked
the button Accept Requested Menu.
In all cases the number of the current and active basic menu is displayed in the
Active status field.
A status field indicates if the menu is being loaded or has been loaded and is
ready to operate. This status is displayed in the Configuration Window and in
the upper right corner of the Global Window:
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100782
Is.Rev
Date:
Safran Data Systems
This document is the property of
3.5
June 1, 2021
.
Page 245