Unless otherwise specified, parameters in this window are described in DRU.
START TIME
STOP TIME
TM BLOCK PER FILE
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL

Figure 141: DRU: Recording Global Window

Storage start time: Day-Hour:Minute:Second
Storage stop time: Day-Hour:Minute:Second
Maximum number of TM blocks per recorded File (defines the recorded files
maximum size). If set to 0, the recorded files maximum size will be 2 Gbytes.
If checkbox "Max" is checked, file maximum size is almost infinite, and one
TM file is recorded for the recording session.
Start writing data to the disk.
Stop writing data.
Show recorded reports (see below).
To access to the erase functions by DRU (Refer to the paragraph "Global Disk
and Memory Management window).