Operating System And Files Architecture; Introduction; Files Architecture; Files Associated With Monitoring & Control Software - Safran CORTEX Series User Manual

High data rate receiver
Table of Contents

Advertisement

4.4

Operating System and files architecture

4.4.1

Introduction

From the release E9R0, the Cortex HRD units come with Windows 7 embedded operating system in
place of the former Windows 2000 and Windows XP.
Depending on the Operating System, the Cortex HDR software and files can be found in different
directories. The paths of these different directories are given in the following paragraphs.
To improve security, with Windows 7, the Cortex user does not have access to C drive anymore. The
configurations files have been moved to D drive.
4.4.2

Files Architecture

4.4.2.1
Files associated with Monitoring & Control Software
FILE
MCS Application
C:\Program Files\ZDS\CrtxMcs
MCS Files
D:\ZDS\Data\HDR\CrtxMcs\DefaultConfig
D:\ZDS\Data\HDR\CrtxMcs\DefaultConfig_ref
(and subdirectories)
User's MCS Files D:\ZDS\Data\HDR\CrtxMcs\UserConfig
4.4.2.2

Files associated with the Signal Processing Software

FILE
SPS Application
C:\Program Files\ZDS\crtxnt
Menu List
D:\ZDS\Data\HDR\crtxnt\Menus
Menu CTX Files
D:\ZDS\Data\HDR\crtxnt\Menus\CTX
D:\ZDS\Data\HDR\crtxnt\Menus\CTX_ref
User's CTX Files
D:\ZDS\Data\HDR\crtxnt\NameTable.txt
D:\ZDS\Data\HDR\crtxnt\SatCnfXX.ctx
(with XX = 01 to 10)
BER Files
D:\ZDS\Data\HDR\crtxnt\BER
VCM Files
D:\ZDS\Data\HDR\crtxnt\VCM
DVB S2 & SCCC
D:\ZDS\Data\HDR\crtxnt\VCM\gamma
Gamma Files
FIR Files
D:\ZDS\Data\HDR\crtxnt\fir
Test Definition
D:\ZDS\Data\HDR\crtxnt\TEST
Files
Script Files
D:\ZDS\Data\HDR\crtxnt\Qual
D:\ZDS\Data\HDR\crtxnt\Scripts
(and subdirectories)
Storage
D:\ZDS\Data\HDR\Storage
Definition Files
FTP Sorting Files
D:\ZDS\Data\HDR\ftp
(and subdirectories)
CFDP Sorting
D:\ZDS\Data\HDR\cfdp
Files
(and subdirectories)
Log Files
D:\ZDS\Data\HDR\log
STI Logging Files D:\ZDS\Data\HDR\log\param_surv
© Safran Data Systems – IMP000074 e14r1
HIGH DATA RATE RECEIVER
HDR-4G+ USER'S MANUAL
WINDOWS 7
WINDOWS 7
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100782
Is.Rev
3.5
Date:
June 1, 2021
WINDOWS 2000 AND XPE
C:\Program Files\IN-SNEC\CrtxMcs
C:\Program Files\IN-SNEC\CrtxMcs\DefaultConfig
C:\Program Files\IN-SNEC\CrtxMcs\DefaultConfig_ref
(and subdirectories)
C:\Program Files\IN-SNEC\CrtxMcs\UserConfig
WINDOWS 2000 AND XPE
C:\Program Files\IN-SNEC\crtxnt
C:\Program Files\IN-SNEC\crtxnt\Menus
C:\Program Files\IN-SNEC\crtxnt\Menus\CTX
C:\Program Files\IN-SNEC\crtxnt\Menus\CTX_ref
C:\Program Files\IN-SNEC\crtxnt\NameTable.txt
C:\Program Files\IN-SNEC\crtxnt\SatCnfXX.ctx
(XX = 01 to 10)
C:\Program Files\IN-SNEC\crtxnt\BER
C:\Program Files\IN-SNEC\crtxnt\VCM
C:\Program Files\IN-SNEC\crtxnt\VCM\gamma
C:\Program Files\IN-SNEC\crtxnt\fir
C:\Program Files\IN-SNEC\crtxnt\TEST
C:\Program Files\IN-SNEC\crtxnt\Qual
C:\Program Files\IN-SNEC\crtxnt\Scripts
(and subdirectories)
D:\ZDS\Data\HDR\Storage
C:\Program Files\IN-SNEC\ftp
(and subdirectories)
C:\Program Files\IN-SNEC\cfdp
(and subdirectories)
C:\Program Files\IN-SNEC\log
C:\Program Files\IN-SNEC\log\param_surv
Safran Data Systems
.
Page 229

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents