Calculating The Fiber-Optic Cable Power Margin For Ex Series Devices - Juniper EX8208 Hardware Manual

Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

To calculate the worst-case estimate for fiber-optic cable power budget (P
1. Determine values for the link's minimum transmitter power (P
For example, here, (P
(dBm).
P
= – 15 dBm
T
P
= – 28 dBm
R
NOTE:
See the specifications for your transmitter and receiver to find the minimum transmitter
power and minimum receiver sensitivity.
2. Calculate the power budget (P
– 15 dBm – (–28 dBm) = 13 dBm

Calculating the Fiber-Optic Cable Power Margin for EX Series Devices

Calculate the link's power margin when planning fiber-optic cable layout and distances to ensure that
fiber-optic connections have sufficient signal power to overcome system losses and still satisfy the minimum
input requirements of the receiver for the required performance level. The power margin (P
of power available after attenuation or link loss (LL) has been subtracted from the power budget (P
When you calculate the power margin, you use a worst-case analysis to provide a margin of error, even
though all the parts of an actual system do not operate at worst-case levels. A power margin (P
than zero indicates that the power budget is sufficient to operate the receiver and that it does not exceed
the maximum receiver input power. This means the link will work. A (P
insufficient power to operate the receiver. See the specification for your receiver to find the maximum
receiver input power.
Before calculating the power margin:
Calculate the power budget (see
on page
132).
To calculate the worst-case estimate for the power margin (P
1. Determine the maximum value for link loss (LL) by adding estimated values for applicable link-loss
factors—for example, use the sample values for various factors as provided in
(here, the link is 2 km long and multimode, and the (P
) and (P
) are measured in decibels, and decibels are referred to one milliwatt
T
R
) by subtracting (P
B
"Calculating the Fiber-Optic Cable Power Budget for EX Series Devices"
) for the link:
B
) and minimum receiver sensitivity (P
T
) from (P
):
R
T
) that is zero or negative indicates
M
) for the link:
M
) is 13 dBm):
B
).
R
) is the amount
M
).
B
) greater
M
Table 61 on page 134
133