Juniper EX8208 Hardware Manual page 48

Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

Table 13: LCD Panel Menu Options for the EX8200 Switch (continued)
Menu
Description
The Maintenance menu has the following options:
SYSTEM HALT?—Choose one of the following:
Press Enter to halt the primary SRE module in an EX8208 switch or to halt the primary RE module
in an EX8216 switch. Press Enter again to confirm the halt.
In a base configuration switch, the primary SRE or RE module will be gracefully halted but not
powered off. Press Enter on your management device or power cycle the switch to bring the
switch back up.
In a redundant configuration, the backup SRE or RE module takes over the primary role when the
primary SRE or RE module is halted. To completely halt the switch, use the request system halt
other-routing-engine CLI command to halt the backup SRE or RE module before halting the
primary SRE or RE module. Press Enter on your management device or power cycle the switch
to bring the switch back up.
See
"EX8208 Switch Configurations" on page 27
on configuration types.
Press Menu to go to the next option in the Maintenance menu.
SYSTEM REBOOT?—Choose one of the following:
Press Enter to reboot the primary SRE or RE module. Press Enter again to confirm the reboot.
Press Menu to go to the next option in the Maintenance menu.
LOAD RESCUE?—Choose one of the following:
Press Enter to roll back the switch to the previous valid configuration. Press Enter again to confirm
the rollback.
Press Menu to go to the next option in the Maintenance menu.
FACTORY DEFAULT?—Choose one of the following:
Press Enter to restore the switch to the factory default configuration. Press Enter again to confirm
the restoration. The LCD panel flashes a success or failure message and returns to the Idle menu.
Press Menu to go to the next option in the Maintenance menu.
ENTER EZSETUP?—Choose one of the following:
Press Enter to launch EZSetup. Press Enter again to confirm the launch.
EZSetup configures DHCP and enables the J-Web user interface on the switch. The LCD panel
flashes a success or failure message for approximately 10 seconds and returns to the Idle menu.
Press Menu to go to the next option in the Maintenance menu.
NOTE:
EXIT MAINT MENU?—Choose one of the following:
Press Enter to exit the Maintenance menu.
Press Menu to return to the SYSTEM HALT option.
You can use the EZSetup option only if the switch is in the factory default configuration.
or EX8216 Switch Configurations for information
48

Advertisement