Juniper EX8208 Hardware Manual page 323

Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

FPC 3
FPC 5
Table 94 on page 323
lists the output fields for the show chassis temperature-thresholds command.
Output fields are listed in the approximate order in which they appear.
Table 94: show chassis temperature-thresholds Output Fields
Field Name
Item
Fan speed
Yellow or amber alarm
Red alarm
Fire Shutdown
When a temperature alarm is triggered, you can identify the condition that triggered it by running the
show chassis environment command to display the chassis temperature values for each component and
comparing those with the temperature threshold values, which you can display by running the show chassis
temperature-thresholds command.
For example, for FPC 3:
If the temperature of FPC 3 exceeds 55° C, the output indicates that the fans are operating at a high
speed (no alarm is triggered).
If the temperature of FPC 3 exceeds 65° C, a yellow alarm is triggered to indicate that one or more fans
have failed.
If the temperature of FPC 3 exceeds 75° C, a yellow alarm is triggered to indicate that the temperature
threshold limit is exceeded.
55
60
75
55
60
75
Field Description
Chassis component. You can configure for the threshold information for components such as the chas
display in the output. By default, information is displayed only for the chassis and the Routing Engines
Temperature thresholds, in degrees Celsius, for the fans to operate at normal and at high speed.
Normal—The temperature threshold at which the fans operate at normal speed and when all the fan
High—The temperature threshold at which the fans operate at high speed or when a fan has failed o
NOTE:
An alarm is not triggered until the temperature exceeds the threshold settings for a yellow or
Temperature threshold, in degrees Celsius, that trigger a yellow or amber alarm.
Normal—The temperature threshold that must be exceeded on the component to trigger a yellow o
Bad fan—The temperature threshold that must be exceeded on the component to trigger a yellow o
Temperature threshold, in degrees Celsius, that trigger a red alarm.
Normal—The temperature threshold that must be exceeded on the component to trigger a red alarm
Bad fan—The temperature threshold that must be exceeded on the component to trigger a red alarm
Temperature threshold, in degrees Celsius, for the switch to shut down.
65
105
80
65
90
80
323
110
95