Table 61: Estimated Values for Factors Causing Link Loss
Link-Loss Factor
Higher-order mode losses (HOL)
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
Clock Recovery Module (CRM)
NOTE:
For information about the actual amount of signal loss caused by equipment and
other factors, see your vendor documentation for that equipment.
2. Calculate the (P
) by subtracting (LL) from (P
M
P
– LL = P
B
M
(13 dBm) – (0.5 dBm [HOL]) – ((5) * (0.5 dBm)) – ((2) * (0.5 dBm)) – ((2 km) * (1.0 dBm/km)) – (1 dB
[CRM]) = P
M
13 dBm – 0.5 dBm – 2.5 dBm – 1 dBm – 2 dBm – 1 dBm = P
P
= 6 dBm
M
Estimated Link-Loss Value
Multimode—0.5 dBm
Single mode—None
Multimode—None, if product of
bandwidth and distance is less than
500 MHz/km
Single mode—None
0.5 dBm
0.5 dBm
Multimode—1 dBm/km
Single mode—0.5 dBm/km
1 dBm
):
B
Sample (LL) Calculation Values
0.5 dBm
0 dBm
0 dBm
0 dBm
This example assumes 5 connectors.
Loss for 5 connectors:
(5) * (0.5 dBm) = 2.5 dBm
This example assumes 2 splices. Loss for
two splices:
(2) * (0.5 dBm) = 1 dBm
This example assumes the link is 2 km
long. Fiber attenuation for 2 km:
(2 km) * (1.0 dBm/km) = 2 dBm
(2 km) * (0.5 dBm/km) = 1 dBm
1 dBm
M
134