Table 89: Chassis Alarms for EX8200 Switches (continued)
Component
Alarm Condition
Temperature
The chassis warm
temperature threshold
has been exceeded
and fan speeds have
increased.
The chassis high
temperature threshold
has been exceeded
and the fans are
operating at full speed.
Severity
Remedy
Minor
Bring down the room
(yellow)
temperature, if possible.
Ensure that the airflow
through the switch is
unobstructed.
Major (red)
Bring down the room
temperature, if possible.
Ensure that the airflow
through the switch is
unobstructed.
Minor
(yellow)
Additional
Information
The chassis is warm
and must be cooled
down. The switch is still
functioning normally.
To monitor
temperature:
user@switch> show
chassis environment
To monitor
temperature
thresholds:
user@switch> show
chassis
temperature-thresholds
The chassis is hot and
must be cooled down.
The switch might still
function normally but
is close to shutting
down if it hasn't
already.
To monitor
temperature:
user@switch> show
chassis environment
To monitor
temperature
thresholds:
user@switch> show
chassis
temperature-thresholds