Operation of the Unit
4
Operation of the Unit
4.1
Operation Accessories
4.1.1 With HSP5 cable and without operator
A special cable (Part no. 00.F5.0C0-0001) is necessary for the control of the KEB
COMBIVERT without operator. It is connected between the HSP5-interface X4A and a
serial RS232-PC-interface (COM1 or COM2). The operation takes place via the PC-pro-
gram COMBIVIS.
The HSP5-cable has an integrated level converter. The connection of a serial standard
cable would destroy the PC-interface.
4.1.2 Digital operator (Part no.: 00.F5.060-1000)
As an accessory for the local operation of the KEB COMBIVERT F5 an operator is available.
To prevent malfunctions, the inverter must be brought into nOP status before connecting /
disconnecting the operator (open control release terminal). When starting the inverter, it is
always started with the last stored values or the factory setting.
Interface control
BUS-Operation "LED on"
(only 00.F5.060-2000)
4.1.3 Interface operator (Part No.: 00.F5.060-2000)
The interface operator corresponds to the functional range of the digital operator. However,
it is enhanced by a serial RS232/485-interface.
5
4
3
2
1
9
8
7
6
A RS232-cable is needed to connect the interface operator with the PC. The assignment is
represented on the following page.
44
START
ENTER
FUNC.
F/R
SPEED
STOP
ANTRIEBSTECHNIK
ANTRIEBSTECHNIK
PIN RS485 Signal Meaning
1
–
–
2
–
TxD
3
–
RxD
4
A'
RxD-A Receiver signal A/RS485
5
B'
RxD-B Receiver signal B/RS485
6
–
VP
7
C/C' DGND Data reference potential
8
A
TxD-A Transmitter signal A/RS485
9
B
TxD-B Transmitter signal B/RS485
5-digit LED display
Operating / Error display
Normal "LED on"
Error "LED blinks"
Double function keyboard
RS232/RS485
(only 00.F5.060-2000)
reserved
Transmitter signal/RS232
Receiver signal/RS232
Voltage supply - Plus +5V (I
= 10 mA)
max