J-10 Compaq ServerNet II PCI Adapter and Switch Installation Guide

snetSwitchSANManFailover

ServerNet II Switch SANMan failure has been detected.
Specific Trap:
Severity:
Summary:
Enable:
Disable:
Returned Variable
snetSwitchPrimarySANManSNetID
snetSwitchPrimarySANManName
snetSwitchBackupSANManSNetID
snetSwitchBackupSANManName
snetSwitchFailoverEventType
Possible Cause or Condition
Primary backup SANMan has failed
Powered off
Hung, doing nothing
Maintenance
108
Minor
SANMan failover detected. Primary SANMan is snetSwitchPrimarySANManSnetID
(snetSwitchPrimarySANManName), Backup SANMan is
snetSwitchBackupSANManSNetID (snetSwitchBackupSANManName). Failure type is
snetSwitchFailoverEventType.
Always enabled
Cannot be disabled
Contains the SNID of the current primary SANMan if
snetSwitchFailoverEventType = 2 or 4
Contains the SNID of the new primary SANMan if
snetSwitchFailoverEventType = 3
Contains the SNID of the new backup SANMan if
snetSwitchFailoverEventType = 5
Name of the current primary SANMan in the ServerNet II SAN.
Contains the SNID of the current backup SANMan if
snetSwitchFailoverEventType = 2 or 4
Contains the SNID of the fail primary SANMan if
snetSwitchFailoverEventType = 3 or 5
Name of the current backup SANMan in the ServerNet II SAN.
The type of failure detected:
2 = Backup not reachable
3 = Backup took over
4 = Primary not reachable
5 = Primary took over
Indicates
Possible Solution
Apply power
Reboot
Not a problem, just restart when finished