Table E-2
SANMan Event Log Messages
Event ID
Type
0x27
Information
0x28
Information
0x30
Error
0x31
Error
0xA
Error
0xB
Error
0xC
Error
0xD
Error
continued
Event Message: ServerNet ID successfully read from the X switch.
Corrective Action: None
Event Message: ServerNet ID successfully read from the Y switch.
Corrective Action: None
Event Message: ServerNet II Port X is connected to a Y switch.
Corrective Action: Check the ServerNet II port connections of the node.
Event Message: ServerNet II Port Y is connected to a X switch.
Corrective Action: Check the ServerNet II port connections of the node.
Event Message: ServerNet ID could not be read from the X switch.
Corrective Action:
Check the cable connections
Verify that the X-fabric ServerNet II Switch is
powered on.
Event Message: ServerNet ID could not be read from the Y switch.
Corrective Action:
Check the cable connections
Verify that the Y-fabric ServerNet II Switch is
powered on.
Event Message: ServerNet ID from the X switch does not match local ServerNet ID found
in the RTD.
Corrective Action:
Check the cable connections
Verify that the X-fabric ServerNet II Switch is correctly installed on the SAN and powered
on.
Event Message: The ServerNet ID from the Y switch does not match local ServerNet ID
found in the RTD.
Corrective Action:
Check the connections
Verify that the Y-fabric ServerNet II Switch is correctly installed and powered on.
Use the SANUTIL to verify the SAN configuration.
If the problem persists, reconfigure the Y-fabric ServerNet II Switch.
ServerNet II Event Log Messages E-7