Compaq ServerNet ServerNet II Installation Manual page 104

Pci adapter and switch
Hide thumbs Also See for ServerNet ServerNet II:
Table of Contents

Advertisement

E-2 ServerNet II PCI Adapter and Switch Installation Guide
Table E-1 shows ServerNet II PCI Adapter event log messages.
Event ID
Type
5
Information
10
Information
11
Information
12
Information
13
Information
Table E-1
PCI Adapter Event Log Messages
Event Message and Corrective Action
Event Message: ServerNet driver is installed.
Corrective Action: None
Event Message: SPAD has determined that the local link to the X fabric has gone down (or
the cable is unplugged).
Corrective Action: Ensure the X cable is properly installed to the X port on the Adapter.
Event Message: SPAD has determined that the local link to the Y fabric has gone down (or
the cable is unplugged).
Corrective Action: Make sure the Y cable is properly installed to the Y port on the Adapter.
Event Message: SPAD has determined that the local link to the X fabric of this node is
available again.
Corrective Action: None required.
Event Message: SPAD has determined that the local link to the Y fabric of this node is
available again.
Corrective Action: None required