G-22 ServerNet II PCI Adapter and Switch Installation Guide
Failed Link between Computer and Switch
This failure was caused by disconnecting one end of the SAN cable that connected computer
HW-TB6-S12 and Port 3 of Switch-X. This failure prevents transactions between computer
HW-TB6-S12 and the SAN on the Switch-X fabric (local computer port X). The resulting
example is analogous to problems that might occur with the following:
Defective, loose, missing or disconnected cable
I
Defective ServerNet II PCI Adapter in the computer
I
Defective daughter card in the Switch
I
HW-TB6-S03
0
1
Port 1
Port 3
0
1
HW-TB6-S12
Figure G-25. Failed link between computer HW-TB6-S12 and Switch-X
Switch X
Port 2
ServerNet
88
Port 0
Switch Y
Port 1
88
Port 3
HW-TB6-S10
0
1
Port 2
ServerNet
Port 0
0
1
HW-TB6-S11