Compaq ServerNet ServerNet II Installation Manual page 143

Pci adapter and switch
Hide thumbs Also See for ServerNet ServerNet II:
Table of Contents

Advertisement

G-20 ServerNet II PCI Adapter and Switch Installation Guide
============================
Results of the Topology Test
============================
The Topology Test FAILED.
This test was run from (Local Host) computer 'HW-TB6-S11'.
The following 6 nodes are configured in the SAN. Their names
and Globally Unique Ids (GUIDs) are given.
HW-TB6-S03
HW-TB6-S10
HW-TB6-S11
HW-TB6-S12
SwitchX
SwitchY
The following 1 nodes are configured in the SAN but were
not found. They might have failed or be turned off. Their names
and Globally Unique Ids (GUIDs) are given.
SwitchY
SAN node 'HW-TB6-S10' GUID {0x0053 0x0001c726 0F1080}
has at least 1 of its ServerNet ports mis-connected. The
following are the connections for all of the node's ports.
Expected and actual connections are given for mis-connected
ports. Either reconfigure the SAN topology using the
SANUtil application or manually fix the cable mis-
connections.
PORT
0 EXPECTED
PORT
1 EXPECTED
PORT
1 ACTUAL
SAN node 'HW-TB6-S11' GUID {0x0053 0x0001c726 0F1000}
has at least 1 of its ServerNet ports mis-connected. The
following are the connections for all of the node's ports.
Expected and actual connections are given for mis-connected
ports. Either reconfigure the SAN topology using the
SANUtil application or manually fix the cable mis-
connections.
PORT
0 EXPECTED
PORT
1 EXPECTED
PORT
1 ACTUAL
SAN node 'SwitchY' GUID {0x0053 0x00000015 V0KVWJ}
has at least 4 of its ServerNet ports mis-connected. The
following are the connections for all of the node's ports.
Expected and actual connections are given for mis-connected
ports. Either reconfigure the SAN topology using the
SANUtil application or manually fix the cable mis-
connections.
PORT
0 EXPECTED
PORT
0 ACTUAL
PORT
1 EXPECTED
PORT
1 ACTUAL
PORT
2 EXPECTED
PORT
2 ACTUAL
PORT
3 EXPECTED
PORT
3 ACTUAL
PORT
4 EXPECTED
PORT
5 EXPECTED
PORT
6 EXPECTED
PORT
7 EXPECTED
PORT
8 EXPECTED
PORT
9 EXPECTED
PORT
10 EXPECTED
PORT
11 EXPECTED
SAN node 'HW-TB6-S12' GUID {0x0053 0x0001c726 0F10C0}
has at least 1 of its ServerNet ports mis-connected. The
following are the connections for all of the node's ports.
Expected and actual connections are given for mis-connected
ports. Either reconfigure the SAN topology using the
SANUtil application or manually fix the cable mis-
connections.
PORT
0 EXPECTED
PORT
1 EXPECTED
PORT
1 ACTUAL
SAN node 'HW-TB6-S03' GUID {0x0053 0x0001c726 0F1040}
has at least 1 of its ServerNet ports mis-connected. The
following are the connections for all of the node's ports.
Expected and actual connections are given for mis-connected
ports. Either reconfigure the SAN topology using the
SANUtil application or manually fix the cable mis-
connections.
PORT
0 EXPECTED
PORT
1 EXPECTED
PORT
1 ACTUAL
Figure G-23. Example 20 Results of the Topology Test Running on computer HW-TB6-S11
GUID {0x0053 0x0001c726 0F1040}
GUID {0x0053 0x0001c726 0F1080}
GUID {0x0053 0x0001c726 0F1000}
GUID {0x0053 0x0001c726 0F10C0}
GUID {0x0053 0x00000015 V0H961}
GUID {0x0053 0x00000015 V0KVWJ}
GUID {0x0053 0x00000015 V0KVWJ}
GUID
{0x0053 0x00000015 V0H961}
GUID
{0x0053 0x00000015 V0KVWJ}
GUID
{}
GUID
{0x0053 0x00000015 V0H961}
GUID
{0x0053 0x00000015 V0KVWJ}
GUID
{}
GUID
{0x0053 0x0001c726 0F1000}
GUID
{}
GUID
{0x0053 0x0001c726 0F1040}
GUID
{}
GUID
{0x0053 0x0001c726 0F1080}
GUID
{}
GUID
{0x0053 0x0001c726 0F10C0}
GUID
{}
GUID
GUID
GUID
GUID
GUID
GUID
GUID
GUID
GUID
{0x0053 0x00000015 V0H961}
GUID
{0x0053 0x00000015 V0KVWJ}
GUID
{}
GUID
{0x0053 0x00000015 V0H961}
GUID
{0x0053 0x00000015 V0KVWJ}
GUID
{}
NAME 'SwitchX'
NAME 'SwitchY'
NAME 'SwitchX'
NAME 'SwitchY'
NAME 'HW-TB6-S11'
NAME 'HW-TB6-S03'
NAME 'HW-TB6-S10'
NAME 'HW-TB6-S12'
NAME 'SwitchX'
NAME 'SwitchY'
NAME 'SwitchX'
NAME 'SwitchY'

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servernet ii

Table of Contents