FusionModule2000-S Smart Modular Data Center
User Manual
2.
Step 6 Configure NAT on the IVS1800.
(1) Configure the MU:
1.
2.
3.
Issue 03 (2021-07-15)
Figure 5-47 Configuring the server (Single Mode by default)
NO TE
Set Business IP to XXX.XXX.XXX.XXX, Subnet mask to 255.255.255.0, and Gateway IP
to XXX.XXX.XXX.XXX. The values here are examples. The actual values may vary.
Change the PC IP address to an address in the network segment of the new
IVS1800 IP address, enter the IVS1800 IP address in the address box of the
Internet browser, and log in to the OMU portal system.
Choose Maintenance > Unified Configuration, set Module Name to MU,
and click Search.
Click Edit in the record where the value of Parameter Name is MUNNatIP,
set the external IP address of the IVS1800, and click Save.
Figure 5-48 Setting the external IP address of the MU
Click Edit in the row where the value of Parameter Name is
NatRtspServerPort, and set the NAT port number of the MU. Ensure that the
setting is the same as the NAT mapped port number configured on the
firewall. Click Save.