9.4 Pneumatic maintenance

Drain the air preparation condensate
What: Condensate drain.
When: When the condensate level is approximately 10 mm below the filter element.
How: Turn the drainage screw at the bottom of the bowl in an counterclockwise
direction as seen from below. The condensate will then flow out.
Replace the MS6-LFP-E filter cartridge
What: Replace the MS6-LFP-E filter cartridge.
When: Depending on the quality of the compressed air, generally 1–2 times/year,
or when the air flow becomes to low.
How:
xx1900000383
Figure 9.1: Opening the filter housing
Product manual - FlexLoader SC 6000
3HAC051768-001 Revision: D
1 Exhaust the unit.
2 Push and hold the blue slider bar in the direction of the arrow.
3 Turn the filter bowl in an anti-clockwise direction as seen from below.
4 Pull the filter bowl away from the unit.
5 Turn the filter plate in an anti-clockwise direction.
6 Replace the filter cartridge if the pores are dirty. Grasp the filter cartridge
only at the lower end when it is new.
7 Clean the bowl with water, soap solution (max. +60 °C), or petroleum ether
(free of aromatic compounds).
8 Fit the individual parts again in the reverse order. Position the slider bar on
the filter bowl facing the large recess in the housing and ensure that it clicks
into place when the end stop is reached.
© Copyright 2014-2020 ABB. All rights reserved.
9 Maintenance
9.4 Pneumatic maintenance
Continues on next page
139