Electrical Maintenance - ABB FlexLoader SC 6000 Product Manual

Table of Contents

Advertisement

9 Maintenance

9.3 Electrical maintenance

9.3 Electrical maintenance
Robot, control cabinet
What: Refer to the robot product manual for more information.
Illumination
What: Change the illumination units in the illumination tower.
When: When the illumination units are approaching the end of their service life, or
when the first illumination unit breaks, it's recommended to replace all the remaining
ones at the same time.
How: Remove the illumination unit from the holder and replace it by a new
component.
If only one illumination unit breaks after a maximum of six months, it is sufficient
to replace that particular unit only.
Sensors and reflectors
What: Check that all sensors and sensor reflectors (if any) are intact, clean and
secured properly.
When: Check and clean when necessary, depending on the amount of dirt that
comes from the details and the surrounding. Replace if necessary.
Check the safety functions
What: Check all emergency stops and emergency and safety switches.
When: Check every month and fix when necessary.
Electrical function check
What: Check all electrical functions, breakers and limit position functions
When: Once / month
Check the cables and cable racks
What: Check the cables and cable racks.
When: Every 3 months.
How: Inspect the entire cable rack (fixing points, dirt deposits, wear) and remedy
any breaks. Check all cables. Replace any damaged cables. Extend cables that
rub against sharp edges.
Check the connections
What: Check the connections.
When: Every 3 months.
How: Inspect all connections and make sure that they are secured properly and
that there is no risk of play.
138