E Frequency inverter

General
This document describes the parameter settings of the frequency inverter ABB
ACS355 which is used in the FlexLoader SC 6000.
The document specifies the settings of the essential parameters that are required
for tuning the FlexLoader SC 6000. Further optimization and settings can be done,
for this refer to User's manual ACS355 user's manual (3AUA0000066143), which
can be found on the ABB website.
This manual refers only to the English user interface of the frequency inverter. For
other languages, refer to the applicable language editions of the manual on the
ABB website.
Overview of the frequency inverter ACS355
xx1800001095
Figure E.1: Overview of the frequency inverter ACS355
1. LCD display – divided into five areas:
Product manual - FlexLoader SC 6000
3HAC051768-001 Revision: D
a. Upper left – Control location:
-
LOC: drive control is local, that is, from the control panel.
-
REM: drive control is remote, such as the drive I/O or fieldbus.
b. Upper right – the unit of the displayed value.
c. Center – variable. Generally shows parameter and signal values, menus
or lists, but can also show error and alarm codes.
d. Lower left and center – panel operation state:
-
OUTPUT: Output mode.
-
PAR: Parameter mode.
-
MENU: Main menu.
-
FAULT: Fault mode.
© Copyright 2014-2020 ABB. All rights reserved.
E Frequency inverter
Continues on next page