4 Commissioning

4.2 Powering on the FlexLoader SC 6000

4.2 Powering on the FlexLoader SC 6000
58
1 Turn on the main power supply. Wait until all devices have started up.
2 Perform a power on safety check:
Press and restore at least one internal FlexLoader SC 6000 emergency
stop button.
Reset the emergency stop.
Open and close at least one internal FlexLoader SC 6000 cell door.
Reset the door status by shortly turning the reset key.
Optionally, if a light curtain is present, a long light curtain reset may
be needed (0.5 s) first, followed by a second reset for the whole cell.
Refer to the safety manual for more detailed information.
3 Check the function of the external emergency stop
4 Check the function of the external protective stop (if present).
DANGER
Do not continue to work until the safety circuits are functioning correctly.