Edge [ii] Controller Operation Manual
SECTION 10 – STARTUP, STATUS, FAULT MESSAGES
TABLE 10-1: Edge Controller Fault Messages
#
FAULT MESSAGE
66
Ignition Monitor
67
No Flow Safety Lockout
68
Ignition Spark Fault
69
Pre Ignition
70
Cleaning Igniter
71
Too Many Cycles In 24 Hours
72
Too Many Ovrtmps In 24 Hours
73
Air Sensor Fault
74
Auto Diagnostic Mode ACTIVE
75
Auto Diagnostic Mode COMPLETED
76
Auto Diagnostic Mode ABORTED
77
DHW Heating Active
78
Boiler Cooling Off
79
BST Network Temp Sensor Fault
80
BST Network Temp Com Fault
81
BST Local Header Sensor Fault
82
BST Net Outdoor Sensor Fault
83
BST Net Outdoor Com Fault
84
BST Local Outdr Sensor Fault
85
BST Client Com Fault
86
O2 Cal Purge
87
Auto Calibration In Progress
88
Autocal Finished
89
O2 Sensor Out Of Range
90
O2 Warning Service Required
91
Wait Sensor Warm-up
92
Air Pump Failed O2 Trim Disabled
93
onAER Communication failed
94
Isolation Valve Stuck Open
95
Isolation Valve Stuck Closed
96
Maintenance Overdue
97
Maintenance Due Soon
98
BAS System Disable
OMM-139_E
8/25/2020
DESCRIPTION
The ignition spark monitor indicated no or out of
range spark.
Not used
The O
is above normal operating limits.
2
The recirculation pump has failed.
Displayed during ignition sequence during the
Spark Cleaning cycle.
The number of cycles experienced by the unit
exceeded the allowable limit.
The number of over-temperature events
exceeded the allowable limit.
The Air Temp sensor has malfunctioned.
The unit is in Auto Diagnostic Mode
Auto Diagnostic Mode has completed
Auto Diagnostic Mode has aborted
The unit is actively heating domestic hot water.
The unit has ceased firing and is now cooling
down.
BST network temp sensor fault.
BST network temp communication fault.
BST local header sensor fault.
BST net outdoor sensor fault.
BST net outdoor communication fault.
BST local outdoor sensor fault.
Communication with a BST Client unit failed.
O
calibration is in purge cycle.
2
O
calibration is underway.
2
O
calibration is complete.
2
O
sensor failed during O
2
AERtrim has reached its limit and O2 level is still
out of range.
The unit is waiting for the O
Air Aductor pump failed, disabling O
functionality (BMK5000-6000 only)
onAER communication failed. No internet
connection.
The isolation valve failed to close as expected.
The isolation valve failed to open as expected.
Scheduled 12- or 24-month maintenance is
overdue.
Scheduled 12- or 24-month maintenance is due
in near future.
Unit is shut down remotely via BAS
Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST
calibration.
2
sensor to turn on.
2
trim
2
Page 190 of 196
TYPE
Message
Not Used
Fault, Manual
Reset
Message
Message
Fault
Fault
Fault
Message
Message
Message
Message
Message
Fault
Fault
Fault
Fault
Fault
Fault
Message
Message
Message
Warning
Warning
Message
Warning
Fault
Warning
Warning
Fault
Warning
Warning
Warning