Advertisement

Quick Links

VT+
Electric actuator
Installation and Operation Manual
UK
Anticondensation
Positionnement
Facteur de marche
Indice de protection
600Nm
intégrée
50%
IP68
POSI
Anticondensation
BLUETOOTH
®
Duty cycle
Enclosure protection
Heater
Positioning

Advertisement

Table of Contents
loading

Summary of Contents for Watts ARA VT+

  • Page 1 Electric actuator Installation and Operation Manual Anticondensation Positionnement Facteur de marche Indice de protection 600Nm intégrée IP68 POSI Anticondensation BLUETOOTH ® Duty cycle Enclosure protection Heater Positioning...
  • Page 2: Table Of Contents

    ENGLISH Index General information ....................... 3  Description  Transport and storage  Maintenance  Warranty  Return of goods  Safety instructions Dimensions ........................4 Electric wiring ....................... 6  Warnings  Multipin connector  Electronic boards  Operating modes ...
  • Page 3: Description

    ENGLISH DESCRIPTION These electric actuators have been designed to perform the control of a valve with 90° rotation. Please consult us for any different application. We cannot be held responsible if the mentioned actuators are used for any other purpose. TRANSPORT AND STORAGE ...
  • Page 4: Dimensions

    ENGLISH Dimensions : 600 and 1000Nm models Star (mm) Depth (mm) ISO 5211 connection Diameter (mm) M threated Depth (mm) Screw number DSBA3600 • Rév. 18/07/2019...
  • Page 5 ENGLISH Dimensions : 1500 and 2400Nm models Star (mm) Depth (mm) ISO 5211 connection Diameter (mm) M threated Depth (mm) Screw number DSBA3600 • Rév. 18/07/2019...
  • Page 6: Electric Wiring

    ENGLISH Electric wiring: warnings  As stipulated in the applicable regulation, the connection to earth contact is compulsory for devices with working voltages exceeding 42V.  The actuator is being always under power, it must be connected to a disconnection system (switch, circuit breaker) to ensure the actuator’s power cut.
  • Page 7: Multipin Connector

    ENGLISH Multipin connector 1 Seal 2 Male connector 3 4 x M3x10 screws 4 4 x CHC M6x30 Stainless steel A2 screws 5 3 x ISO M20 x 1,5 cable glands 6 Connector cover To wire the actuator, unscrew the 4 CHC M6x30 screws, and the 4 M3x10 screws.
  • Page 8 ENGLISH Electronic card High voltage card (SNBA050000) : 100V to 240V AC 50/60Hz and 100V to 300V DC Low voltage card (SNBA051000) : 24V o 48V AC 50/60Hz and 24V to 72V DC POWER SUPPLY 100V to 240V AC 50/60Hz and 100V to 300V DC 24V to 48V AC 50/60Hz and 24V to 72V DC TP/PE 1 Power supply terminal...
  • Page 9 ENGLISH Functioning modes Local control (Bluetooth ® Weekly scheduler (Bluetooth ® Wired (permanent & pulse signal) Positioning (learning mode) Positioning Keyboard local control (available soon) Mode selection Selection confirmation Description  Wireless local control (Bluetooth ® ) : allows the use of the actuator from 20m maximum (in open field). This mode requires a smartphone or a tablet with the ®...
  • Page 10 ENGLISH Permanent wiring Permanent wiring 3-modulating points ON/OFF 13 14 15 16 17 18 13 14 15 16 17 18 Open Close Open Neutral Phase Neutral Phase AC 50/60Hz AC 50/60Hz Wiring • VT+ models with pulse control A feedback signal ( 4- 20mA or 0-10V) is avai- lable from terminal 9 10-11 whichever your...
  • Page 11: Positioning Function

    ENGLISH Positioning function Validation led (pos.1) Led de validation (pos. 2) Learning mode - closed position Learning mode - storage Learning mode - open position Feedback Setpoint signal signal Learning mode  Put the power on  With the « Next Mode » and « Ok Mode » buttons, select the learning mode (the APPR led is on) ...
  • Page 12 ENGLISH Positioning function: wiring Setpoint signal + Setpoint signal feedback + ( feedback - feedback + ( Neutral Phase AC 50/60Hz The 0-10V and 4-20mA feedback signals are not available at the same time. DSBA3600 • Rév. 18/07/2019...
  • Page 13 ENGLISH Bluetooth ® function Wireless local control ® software allows the actuator control with maximum range of 20m (in open field). MART Weekly scheduling ® MART Thanks to software, the actuator can be programmed to schedule up to 20 tasks weekly repeatable. The actuator will become a stand-alone unit.
  • Page 14: Technical Data

    ENGLISH Technical data: 600 and 1000Nm models VT600 VT1000     Implantation Housing: Aluminium + EPOXY coating Materials Drive: Steel + Zn treatment Shafts and screws : Stainless steel Sealing IP68   Environment Both inside and outside (wet environments possible) Operating temperature -20°C to +70°C  ...
  • Page 15 ENGLISH Technical data: 1500 and 2400Nm models VT1500 VT2400     Implantation Housing: Aluminium + EPOXY coating Materials Drive: Steel + Zn treatment Shafts and screws : Stainless steel Sealing IP68   Environment Both inside and outside (wet environments possible) Operating temperature -20°C to +70°C  ...
  • Page 16: Codification

    ENGLISH Codification 1000 . A Star 36 F10/F12 B Star 46 F14 C Star 46 F12/F16 D Special E Keyway bore Ø40 F12/F16 0 Standard 3 Long operating time 100V to 240V 50Hz/ 60Hz and 100V to 300V DC 24V to 48V 50Hz / 60HZ and 24V to 72V DC G 50% 00 3-modulating points + ON-OFF mode...

This manual is also suitable for:

Ara vt600Ara vt1000Ara vt1500Ara vt2400

Table of Contents