Customer Replaceable Units
8. Remove the top cover actuator.
Installing the Top Cover Interlock Sensor
1. Use a 2 mm hex wrench to reinstall the mounting screws (2) that secure the interlock
sensor to the mounting bracket. See
2. Reconnect the top cover sensor cable at the quick disconnect connector.
3. Install three cable ties to secure the sensor cable to the mounting bracket.
4. Use a 2.5 mm hex wrench to reinstall the mounting screws (2) that secure the interlock
actuator to the top cover. See
5. Close the top cover.
6. Power ON the printer.
7. Verify operation by opening and closing the top cover.
8. If the touchscreen displays errors indicating that the cover is not closed, adjust the position
of the actuator.
Figure 45: Top Cover Actuator Mounting Screw Locations