Stratasys F120 User Manual page 150

Shared office 3d printer
Hide thumbs Also See for F120:
Table of Contents

Advertisement

Touchscreen Calibration
4. Once you're finished adjusting for XY and Z, press the Apply button within the Manual Tip
Calibration page and your calibration adjustment(s) will be saved. Press the Close button
to exit the page.
Touchscreen Calibration
You have the option of recalibrating the printer's touchscreen display. Extreme care must be
taken when performing this calibration as an improperly calibrated touchscreen can lead to
button accuracy issues.
After pressing the Apply button, the Close button will appear. Press the Close
button to return to the initial Tip Calibration page.
Repeat
step 1
above to build a calibration part.
Repeat the instructions in
until the support layer matches the model tip slice height ±0.0005 in. (0.01 mm).
A stylus pen should be used when performing this calibration to ensure precise
calibration. Do not use your fingertip to perform this calibration. If a stylus pen is not
available, a pencil eraser may be used.
© Copyright 2020 Stratasys. All rights reserved.
Figure 19: Close Button Location
step 3
above. Continue to check and adjust for Z offset
Manual Tip Calibration
Page 141

Advertisement

Table of Contents
loading

Table of Contents