Tip Calibration
f.
Use the Down button to enter the value obtained in
than the tip's slice height. For example, if you measured an average of 0.0080 in.
(0.2032 mm) for a tip with a slice height of 0.010 in. (0.254 mm), press the Down
button until 0.0080 (0.2032) is displayed within the Slice Height field.
Imperial units
Use the Up button to enter the value obtained in
than the tip's slice height. For example, if you measured an average of 0.0120 in.
(0.3048 mm) for a tip with a slice height of 0.010 in. (0.254 mm), press the Up
button until 0.0120 (0.3048) is displayed within the Slice Height field.
Imperial units
If a Z offset adjustment is required you will need to rebuild the calibration part. To do so:
After entering your Z offset adjustment press the Apply button within the Manual
Tip Calibration page (see
adjustment(s) will be saved. If you continue to change the adjustment values, you
must press the Apply button again to save the changes.
The Cancel button can be used to reset an adjustment value entered prior to
pressing the Apply button. Once the Apply button is pressed, values will be
saved and the printer's calibration settings will reflect the adjustment value
entered. Use caution when entering an adjustment value to ensure it is correct
prior to pressing the Apply button.
© Copyright 2020 Stratasys. All rights reserved.
Figure 17: Z Offset Adjustment
Down button for
adjusting Z offset
Figure 18: Z Offset Adjustment
Up button for
adjusting Z offset
Figure 9 (page 134)
Manual Tip Calibration
step c
above if this value is less
Metric units
step c
above if this value is greater
Metric units