Finding a Remedy
Condition
Support
material is
difficult to
remove from
part
Model material
surface finish
is poor on
downward
facing
surfaces
Support
material
removes too
easily
Material
oozing
Oven not
maintaining
temperatures
Possible Cause
Support material
is embedded in
Adjust the Tip Offset Calibration. See
the vertical
Calibration" (page
surfaces of the
part.
The tip to tip
Repeat Tip Offset Calibration. See
calibration is not
(page
set correctly.
Contact Customer Support or your regional Stratasys office
Moisture in the
material coil box.
(see
Contact Customer Support or your regional Stratasys office
Heater failure.
(see
Close the oven door; the heater turns off while the door is
Oven door open.
open.
Check oven door seal and verify that it is securely affixed to
oven door frame and does not exhibit cuts/tears.
Oven door not
If excessive wear is visible, Contact Customer Support or
sealing.
your regional Stratasys office (see
for contact information).