Stratasys F120 User Manual page 144

Shared office 3d printer
Hide thumbs Also See for F120:
Table of Contents

Advertisement

Tip Calibration
2. Determine the XY Offset Adjustment needed for your printer.
a. Using a magnifier (included in the Welcome Kit), view the relationship between the
b. Determine where on each side (X1, X2, Y1, and Y2) the support toolpath is most
Magnified single side of a calibration
part with a reading of 0.
Support
toolpath
The Apply button will become active when you modify an offset value by dragging
the sliding scale icons or pressing the up and down adjustment buttons.
support calibration toolpath and the alignment indicators to determine the X and Y axis
calibration.
centered between the X-Y alignment indicators (see
numbers on the calibration part represent thousandths of an inch (e.g., 4 = 0.004 in.).
Most
centered
at 0
Alignme
nt
© Copyright 2020 Stratasys. All rights reserved.
Figure 10: Apply button active
Figure 11: Calibration Part
Manual Tip Calibration
Figure 11
or
Figure
Calibration Part
12). The
Page 135