Serial Command Reference

Error Message Enable (EME)

EME
Preference
CONTROL GROUP:
Description
This control enables the displaying of error messages, and determines to which interface the messages are sent.
Error messages can be turned Of or can be sent out the serial port. This setting does not affect messages for
invalid user entries, for which error messages are always displayed.
Valid values are:
• 0 = Off
• 2 = Serial ports
Subcode
<No Subcode >
EXAMPLE:
(EME ?) Get current Error Message Enable state. 
(ESM ?) Set Error Message Enable to send errors out serial ports.

Enable Stealth Mode (ESM)

ESM
Preference
CONTROL GROUP:
Description
Stealth mode extinguishes status LEDs on the projector. Typically this is used in simulation environments where
extraneous light would detract from the scenario (when the scene involves IR).
Subcode
<No Subcode >
EXAMPLE:
(ESM 1) Enable stealth mode.
(ESM ?) Report the stealth mode value.