MBE–Message Box Enable
Enables or disables the displaying of groups of message boxes on the on-screen display.
Commands
Command
Description
MBE+USER <0 | 1>
Enables or disables displaying message
boxes directly triggered by user actions, for
example gamma or lens control message
boxes.
Examples
Set user message boxes to not be displayed:
(MBE+USER 0)
Result:
OFF
Set user message boxes to be displayed:
(MBE+USER 1)
Result:
ON
MDT–Mode Adjustment
Adjusts the horizontal and vertical start position for a signal in the EDID timing table and record the
values in the system to override the timing table.
Run a Save command to keep the settings before exiting. To revert to the original timing table
settings, manually clear each setting. You cannot use the Factory Defaults command to clear these
settings. This command is write only.
Commands
Command
Description
MDT+HPOS nnn
Applies a horizontal offset.
MDT+VPOS nnn
Applies a horizontal offset.
MDT+SAVE n
Saves the settings.
MDT+CLER n
Clears the setting.
Examples
Return the current mode adjustment settings:
GS Series Serial API Commands Technical Reference
020-000814-01 Rev. 1 (06-2015)
Serial API commands
Values
0 = Disables displaying message boxes
directly triggered by user actions
1 = Enables displaying message boxes
directly triggered by user actions (Default)