Adjust the vertical location of the lens up 80 steps:
(LVU 80)
MBE–Message Box Enable
Enables or disables the displaying of groups of message boxes on the on-screen display.
Commands
Command
Description
MBE+USER <0 | 1>
Enables or disables displaying message
boxes directly triggered by user actions, for
example gamma or lens control message
boxes.
Examples
Set user message boxes to not be displayed:
(MBE+USER 1)
Result:
OFF
Set user message boxes to be displayed:
(MBE+USER 0)
Result:
ON
MDT–Mode Adjustment
Adjusts the horizontal and vertical start position for a signal in the EDID timing table and record the
values in the system to override the timing table.
Run a Save command to keep the settings before exiting. To revert to the original timing table
settings, manually clear each setting. You cannot use the Factory Defaults command to clear these
settings.
Commands
Command
Description
MDT?
Returns the current mode adjustment
settings. (Read-only)
MDT+CLER <value>
Clears the setting.
MDT+HPOS <value>
Applies a horizontal offset.
MDT+RDIX <value>
Sets the record index.
DWU1612-HS/DWU2022-HS Technical Reference–Serial Commands
020-103352-01 Rev. 1 (03-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
0 = Enables displaying message boxes
directly triggered by user actions
1 = Disables displaying message boxes
directly triggered by user actions (Default)
Values
One numeric character
Three numeric characters
0 to 19