Test Pattern Grey (Itg); Internal Test Pattern (Itp) - Christie Matrix StIM-WQ User Manual

Table of Contents

Advertisement

Test Pattern Grey (ITG)

ITG
Unsaved
CONTROL GROUP:
Description
Specify the grey level to use for the 'Grey' flat field internal test pattern. Range 0-1023. The level defaults to 512
on power up. This command is on available while the grey test pattern is being displayed.
Subcode
<No Subcode >
Example:
(ITG 512) Set test pattern grey to mid point.

Internal Test Pattern (ITP)

ITP
Unsaved
CONTROL GROUP:
Description
Puts a test pattern on the screen or queries the test pattern currently displayed. Select which test pattern to
display from the list:
0 = Off
1 = Grid
2 = Grey Scale 16
3 = White
Subcode
<No Subcode >
Example:
(ITP 0) Disable test patterns - revert to previous Input signal. 
(ITP 1) Set test pattern to the grid pattern.
Matrix StIM™ WQ/SIM WQ User Manual
020-100883-01 Rev. 2 (06-2013)
Power Up
SUBCLASS:
Power Up
SUBCLASS:
4 = Flat Grey
5 = Black
6 = Checker
7 = 13 Point
ACCESS LEVEL:
Description of Use
ACCESS LEVEL:
8 = Color Bars
12 = Edge Blend
14 = Boresight
Description of Use
Enable, disable or change standard test patterns.
Serial Command Reference
Operator
Operator
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Matrix sim-wq130-002103-01130-003104-01

Table of Contents