Auto Shutdown (Ash); Baud Rate (Bdr) - Christie Matrix StIM-WQ User Manual

Table of Contents

Advertisement

Serial Command Reference

Auto Shutdown (ASH)

ASH
Saved
CONTROL GROUP:
Description
When Auto Shutdown Mode has been selected, and no projector activity has been seen for the activation time-out
period, the projector will enter a Power Saving mode in which the lamps will dim and the shutter close. If this
condition persists for an additional time-out period the projector will automatically go to standby. The presence of
any activity within this is combined interval will cancel Auto Shutdown and return the projector to normal
operation.
Subcode
<No Subcode >
SBTO
ALTO
Examples:
(ASH 1) Turns ON Auto Shutdown Mode. 
(ASH 0) Turns OFF Auto Shutdown Mode.
(ASH+SBTO 10) Sets standby time-out to 10 minutes.
(ASH+ALTO 10) Sets source activity loss time-out to 10 minutes.

Baud Rate (BDR)

BDR
Preference
CONTROL GROUP:
Description
Set the baud rate for a serial communications port. For RS-232 IN and RS-232 OUT, the default is 115200. For RS-
422, the default is 19200. The default communications settings for all ports is 8 data bits, no parity. Valid baud
rates, with the values to select them, are:
0 = 1200 
1 = 2400 
2 = 9600 
3 = 19200
Subcode
PRTA
PRTB
PRTC
Examples:
(BDR+PRTA 6) Set baud rate on port A to 115200 bits per second. 
(BDR+PRTA?) Get baud rate (BDR+PRTA!"115200").
92
Power Down
SUBCLASS:
Power Down
SUBCLASS:
4 = 38400 
5 = 57600 
6 = 115200
ACCESS LEVEL:
Description of Use
Enable or disable Auto Shutdown Operation.
Set the uninterrupted time-out period that must elapse before
projector will enter Standby Mode (The second time-out period
or Standby time-out).
Set the uninterrupted time-out period that must elapse time of
activity loss until Auto Shutdown is activated (The first time-
out period or Activation time-out).
ACCESS LEVEL:
Description of Use
Set the baud rate on port A (RS-232 IN)
Set the baud rate on port B (RS-232 OUT)
Set the baud rate on port C (RS-422)