Target White Point (TWP)

TWP
Preference
CONTROL GROUP:
Description
This command is used to set the ArrayLOC target white-point. Several preset white points are provided in
addition to four user setting white points. The control subcodes provide access to all the presets. Due to the
large number of sub-codes they are not all listed. Instead a simple substitution for the small 'x' is made,
according to the following table:
0
1
2
3
4
5
6
7
8
C
Subcode
SLCT
WHxX
WHxY
WHxT
SWxT
COPY
Examples:
(TWP+SLCT 5) Select User setting 1.
(TWP+WH6X 290) Set User 2 target white x point to 0.290.
(TWP+WH2Y ?) Return value of 6500K setting white y point.
(TWP+SWCT 1) Derive x and y from color temperature setting.
(TWP+WHCT 8000) Set color temperature to 8000K.
(TWP+COPY 4) Copy settings from 9300K to current.
Matrix StIM™ WQ/SIM WQ User Manual
020-100883-01 Rev. 2 (06-2013)
Power Up
SUBCLASS:
3200K
5000K (D50)
6500K (D65)
7500K (D75)
9300K (D93)
User 1
User 2
User 3
User 4
Current
Description of Use
Selects the white point
0 = 3200K
1 = 5000K (D50)
3 = 6500K (D65)
4 = 7500K (D75)
Adjusts the x coordinate of the white color point (0 - 800 with 3 decimal places).
Adjusts the y coordinate of the white color point (0 - 800 with 3 decimal places).
Sets user set color temperature and adjusts the white point x and y coordinates.
Available for user settings if SWxT is set to 1.
Selects whether user presets are generated from white point values (0) or from a
color temperature value (1).
Copy white point settings from preset to current. Value 0-8 for source preset.
Serial Command Reference
Operator
ACCESS LEVEL:
5 = 9300K (D93)
6 = User 1
7 = User 2
8 = User 3
9 = User 4