Serial Communication
Other Special Functions (optional)
To add functionality to the current message, include one or more of the following special characters
between the Function code/Subcode, and the first parameter. If more than one, add them in any
order. See
Flow Control
C
Control Class Inquiry
D
Default value/Text
E
Enable Control Inquiry
G
Access Group Inquiry
H
Return the Help text for a control
L
Return a list of options for 'list' controls
M
Find min/max adjustments (i.e., range)
N
Return the name of the control
T
Return the type of control (i.e. Slidebar etc.)
Data
The value for a given projector state, such as "ON" or "OFF", appears in ASCII-decimal format
directly after the request/reply symbol. You can add an optional space after the symbol (i.e., before
the data) in a set message, but data in replies follow the "!" (exclamation) symbol without a space.
Other details to remember about data:
•
All values returned by the projector (reply messages) have a fixed length, regardless of the
actual value. For a specific parameter, the length will always be the same (e.g. contrast is always
returned as 3 characters, projector number is always returned as 5 characters). The minimum
parameter size is 3 characters. Values that are less than the pre-defined size will be padded with
leading zeros as needed. Parameters which have negative signs (-) are zero padded after the
negative sign, and will have one less digit to make space for the sign.
•
If entering a negative number, there must be a space between the code/subcode, and the value.
For example, (CRM3) and (CRM 3) can both be used when the number is positive. (CRM -2) is
acceptable, but (CRM-2) is not.
•
Data in set messages to the projector do not require padding with zeros.
•
Within each message, multiple parameters of data must be separated by one "space" character.
•
Text parameters are enclosed in double quotes following the data, as in "Name".
80
on page 84.
Matrix StIM™ WQ/SIM WQ User Manual
020-100883-01 Rev. 2 (06-2013)