Appendix 2.12 Program Errors (P) - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

Appendix 2.12 Program Errors (P)

P10 No. of simultaneous axes over
Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
- Divide the alarm block command into two.
- Check the specifications.
P11 Illegal axis address
Details
The axis address commanded by the program does not match any of the ones set by the parameter.
Remedy
- Correct the axis names in the program.
P20 Division error
Details
The issued axis command cannot be divided by the command unit.
Remedy
- Correct the program.
P29 Not accept command
Details
The command has been issued when it is impossible.
- The normal line control command (G40.1, G41.1, G42.1) has been issued during the modal in which
the normal line control is not acceptable.
- The command has been issued during the modal in which the 2-part system synchronous thread
cutting is not acceptable.
Remedy
- Correct the program.
P30 Parity H error
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO code.
Remedy
- Check the paper tape.
- Check the tape puncher and tape reader.
P31 Parity V error
Details
The number of characters per block on the paper tape is odd.
Remedy
- Make the number of characters per block on the paper tape even.
- Set the parameter parity V selection OFF.
P32 Illegal address
Details
An address not listed in the specifications has been used.
Remedy
- Correct the program address.
- Correct the parameter settings.
- Check the specifications.
P33 Format error
Details
The command format in the program is not correct.
Remedy
- Correct the program.