Mitsubishi Electric M700VS Series Setup Manual page 216

Mitsubishi cnc
Table of Contents

Advertisement

【#9420】 DEV3 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial port.
If the output device has a data receiving error (overrun error), decrease the buffer size with this
parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 bytes
3: 8 bytes
4: 16 bytes
5: 64 bytes
【#9421】 DEV3 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "
[ ".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9422】 DEV3 EIA CODE ]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "
] ".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9423】 DEV3 EIA CODE #
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code
"#".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9424】 DEV3 EIA CODE *
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code
"*".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9425】 DEV3 EIA CODE =
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code
"=".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9426】 DEV3 EIA CODE :
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "
: ".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
M700VS Series Setup Manual
Appendix 1.1 User Parameters
199