Other Setting Method; Machine End Stopper Method: Automatic Initialization - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

7.1.3 Other Setting Method

7.1.3.1 Machine End Stopper Method: Automatic Initialization

(1) Select [Param] -> [Abs.Posit.Param.] in the maintenance screen.
Set the following parameters in the "Abs.Posit.Param." screen.
#2049 type (absolute position detection type)
#2054 clpush (current limit)
#2055 pushf (push speed)
#2056 aproch (approach point)
#2059 zerbas (zero point return parameter)
The parameters other than "#2049 type" can be set in the "Zero point set" screen.
(2) Turn the power OFF and ON.
(3) Select [Mainte] -> [To Abs pos.]. The absolute position setting screen will appear.
(4) Select [Axis select]. Enter the axis name (the name set in "#1022 axname2 (2nd axis name), and hold down INPUT
key.
(5) Select [Auto init set] mode.
(6) Set "1" to "#0 Absolute posn set".
(7) Enter the value in "#2 Zero-P".
7.1 Adjusting the Absolute Position Detection System
Parameter
1 (machine end stopper method
isselected)
0 to 100
1 to 999
0 to 999.999
1 (on the grid point immediately
beforethe stopper)
M700VS Series Setup Manual
Setting value
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents