【#2089】 bsax_pl
Not used. Set to "0".
【#2090】 plrapid Rapid traverse rate for super-imposition control
Set the rapid traverse rate for superimposition control.
(Equivalent to "#2001 rapid Rapid traverse rate".)
---Setting range---
1 to 1000000 (mm/min)
【#2091】 plclamp Cutting feed clamp speed for super-imposition control
Set the cutting feed clamp speed for superimposition control.
(Equivalent to "#2002 clamp Cutting feed clamp speed".)
---Setting range---
1 to 1000000 (mm/min)
【#2092】 plG0tL G0 time constant for superimposition control (linear)
Set the G0 time constant (linear) for superimposition control.
(Equivalent to "#2004 G0tL G0 time constant (linear)".)
---Setting range---
1 to 4000 (ms)
【#2093】 plG0t1 G0 time constant for superimposition control (primary delay)
Set the G0 time constant (primary delay) for superimposition control.
(Equivalent to "#2005 G0t1 G0 time constant (primary delay".)
---Setting range---
1 to 5000 (ms)
【#2094】 plG1tL G1 time constant for superimposition control (linear)
Set the G1 time constant (linear) for superimposition control.
(Equivalent to "#2007 G1tL G1 time constant (linear)".)
---Setting range---
1 to 4000 (ms)
【#2095】 plG1t1 G1 time constant for superimposition control (primary delay)
Set the G1 time constant (primary delay) for superimposition control.
(Equivalent to "#2008 G1t1 G1 time constant (primary delay)".)
---Setting range---
1 to 5000 (ms)
【#2096】 crncsp Minimum corner deceleration speed
Set the minimum clamp speed for corner deceleration in the high-accuracy control mode. Normally
set "0".
(Note) This parameter is invalid during SSS control.
---Setting range---
0 to 1000000 (mm/min)
【#2097】 tlml2- Sub side tool setter - direction sensor
Set the sensor position (on sub side) in the (-) direction when using the tool setter on the sub spindle
side.
(Note) In the case of the basic axis and inclined axis of the inclined axis specifications, set the
---Setting range---
-99999.999 to 99999.999 (mm)
position on the orthogonal coordinate.