Advertisement

(3) When using one power supply shared unit by two NC communication bus systems
In systems employing a number of small-capacity drive units, a single power supply unit can be shared by two NC
communication bus systems. In this case, a power supply control axis must be set for each axis of each NC
communication bus.
For basic connection information, refer to the MDS-D/DH Series Instruction Manual.
MDS-D/DH-V2
1st/2nd axis
Connected to the NC
(1st part system)
Optical
communication
cable
MDS-D/DH-V2
8th/9th axis
Connected to the NC
(2nd part system)
Optical
communication
cable
Connections when using one power supply shared by two NC communication bus systems
If the two NC communication bus systems include a spindle drive unit, connect the power
CAUTION
supply unit's CN4 connector to the CN4 connector of the largest capacity spindle drive unit. If
there is no spindle drive unit, connect to the unbalance-axis servo drive unit.
MDS- D/DH -V2
MDS-D/DH-V2
3rd/4th axis
5th/6th axis
MDS-D/DH-V1
MDS-D -SP2
10th axis
11th/12th axis
M700VS Series Setup Manual
2.1 Connecting and Setting the Drive Unit
MDS-D/DH-V1
7th axis
(CV control axis)
CN4
MDS-D/DH-SP
MDS-D/DH-CV
13th axis
(Shared)
(CV control axis)
CN4
CN4
CN9
9