Mitsubishi Electric M700VS Series Setup Manual page 222

Mitsubishi cnc
Table of Contents

Advertisement

【#9610】 LINK PARAM. 2
Bit 2: Specify the control code parity (even parity for the control code).
Select whether to add an even parity to the control code, in accordance with the I/O device
specifications.
0: Not add a parity bit to the control code
1: Add a parity bit to the control code
Bit 3: Parity V
Select whether to enable checking of parity V in one block at the input of the data.
0: Disable
1: Enable
【#9611】 Link PARAM. 3
Not used. Set to "0".
【#9612】 Link PARAM. 4
Not used. Set to "0".
【#9613】 Link PARAM. 5
Not used. Set to "0".
【#9614】 START CODE
Select the code used to command the first transfer of file data.
This parameter is used for a specific user. Normally set "0".
0: DC1 (11H)
1: BEL (07H)
【#9615】 CTRL. CODE OUT
bit 0: NAK output
Select whether to send the NAK code to the host if a communication error occurs in computer link B.
0: Not output the NAK code
1: Output the NAK code.
bit 1: SYN output
Select whether to send the SYN code to the host if NC resetting or an emergency stop occurs in
computer link B.
0: Not output the SYN code.
1: Output the SYN code.
bit 3: DC3 output
Select whether to send the DC3 code to the host when the communication ends in computer link B.
0: Not output the DC3 code.
1: Output the DC3 code.
【#9616】 CTRL. INTERVAL
Not used. Set to "0".
【#9617】 WAIT TIME
Not used. Set to "0".
【#9618】 PACKET LENGTH
Not used. Set to "0".
【#9619】 BUFFER SIZE
Not used. Set to "0".
【#9620】 START SIZE
Not used. Set to "0".