Appendix 1 Explanation of Parameters
【#12890】 aux_PSW10dog2 PSW10 area setting 2
Set "PSW10 area setting" 1 and 2 to specify the area where the position switch 10 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12891】 aux_PSW11dog1 PSW11 area setting 1
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12892】 aux_PSW11dog2 PSW11 area setting 2
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12893】 aux_PSW12dog1 PSW12 area setting 1
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12894】 aux_PSW12dog2 PSW12 area setting 2
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12895】 aux_PSW13dog1 PSW13 area setting 1
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)