Appendix 1 Explanation of Parameters
【#2220(PR)】 SV020 RNG2 Main side detector resolution
Set the number of pulses per revolution of the motor side detector.
OSA18 (-A48) (260,000 p/rev) ----------- SV020 = 260
OSA105 (-A51) (1,000,000 p/rev) ------- SV020 = 1000
OSA166 (-A74) (16,000,000 p/rev) ----- SV020 = 16000
For linear motor
Set the number of pulses of the detector per magnetic pole pitch with SV118.
For direct-drive motor
Set the number of pulses per revolution of the motor side detector.
For 1000 pulse unit resolution detector, set the number of pulses to SV020 in increments of 1000
pulse(kp).
In this case, make sure to set SV118 to "0".
For high-accuracy binary resolution detector, set the number of pulses to four bite data of SV118
(high-order) and SV020 (low-order) in pulse(p) unit.
SV118 = number of pulses / 65536 (when =0, set "-1" to SV118)
SV019 = the remainder of "number of pulses / 65536"
When the NC is C70 and "SV020 > 32767", set "the reminder of above - 65536 (negative number)"
to "SV020".
---Setting range---
When SV118 = 0, the setting range is from 0 to 32767 (kp)
When SV118 ≠ 0
【#2221】 SV021 OLT Overload detection time constant
Normally, set to "60". (For machine tool builder adjustment.)
Related parameters: SV022
---Setting range---
1 to 999 (s)
【#2222】 SV022 OLL Overload detection level
Set the "Overload 1" (Alarm 50) current detection level as percentage to the stall current.
Normally set this parameter to "150". (For machine tool builder adjustment.)
Related parameters: SV021
---Setting range---
110 to 500 (Stall current %)
【#2223】 SV023 OD1 Excessive error detection width during servo ON
Set the excessive error detection width in servo ON.
<Standard setting value>
OD1=OD2= (Rapid traverse rate [mm/min]) / (60×PGN1) / 2 [mm]
When set to "0", the excessive error alarm detection will be ignored.
Related parameters: SV026
---Setting range---
0 to 32767 (mm)
However, when SV084/bitC=1, the setting range is from 0 to 32767 (μm).
(Only for MDS-D/DH and MDS-DM)
324
For M700V,M70V,M70: 0 to 65536 (p)
For C70: -32768 to 32767 (p)