P177 Tool life count active
Details
Registration of tool life management data with G10 was attempted when the "usage data count valid"
signal was ON.
Remedy
- The tool life management data cannot be registered during the usage data count. Turn the "usage
data count valid" signal OFF.
P178 Tool life data entry over
Details
The number of registration groups, total number of registered tools or the number of registrations per
group exceeded the range in the specifications.
Remedy
- Correct the number of registrations.
P179 Illegal group No.
Details
- A duplicate group No. was found at the registration of the tool life management data with G10.
- A group No. that was not registered was designated during the T****99 command.
- An M code command, which must be issued as a single command, coexists in the same block as
that of another M code command.
- The M code commands set in the same group exist in the same block.
Remedy
- Register the tool life data once for one group: commanding with a duplicate group No. is not allowed.
- Correct to the group No.
P180 No spec: Drilling cycle
Details
A fixed cycle command (G72 - G89) was issued though it is out of specifications.
Remedy
- Check the specifications.
- Correct the program.
P181 No spindle command (Tap cycle)
Details
Spindle rotation speed (S) has not been commanded in synchronous tapping.
Remedy
- Command the spindle rotation speed (S) in synchronous tapping.
- When "#8125 Check Scode in G84" is set to "1", enter the S command in the same block where the
synchronous tapping command is issued.
P182 Synchronous tap error
Details
- Connection to the main spindle unit was not established.
- The synchronous tapping was attempted with the spindle not serially connected under the multiple-
spindle control I.
Remedy
- Check connection to the main spindle.
- Check that the main spindle encoder exists.
- Set 1 to the parameter #3024 (sout).
P183 No pitch/thread number
Details
The pitch or number of threads has not been commanded in the tap cycle of a fixed cycle for drilling
command.
Remedy
- Specify the pitch data and the number of threads by F or E command.