【#1163(PR)】 No rio RIO connection detection invalid
Select whether to enable or disable RIO connection detection.
0: Enable
1: Disable
If your I/O consists of only cards such as CC-LINK, setting this parameter to "1" will avoid the RIO
communication cutoff alarm.
【#1164(PR)】 ATS Automatic tuning function
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
【#1166】 fixpro Fixed cycle editing
Select a type of program dealt on the edit/program list/data in/out screen, general program, fixed
cycle, or machine tool builder macro program.
0: General programs can be edited, etc.
1: Fixed cycles can be edited, etc.
Password No.: The machine tool builder macro programs can be edited, etc.
---Setting range---
0 to 99999999
【#1167】 e2rom
Not used. Set to "0".
【#1168】 test Simulation test
Select the test mode for the control unit.
In the test mode, test is performed with a hypothetical reference position return complete even
though the real reference position return hasn't been completed. This is limited to test operation of
the control unit itself, and must not be used when the machine is connected.
0: Normal operation mode
1: Test mode
【#1169】 part system name Part system name
Set the name of each part system.
This must be set only when using multi-part system.
This name will be displayed on the screen only when the part systems must be identified.
Use a max. of four alphabetic characters or numerals.
---Setting range---
A max. of four alphabetic characters or numerals.
【#1170】 M2name Second miscellaneous code
Set this address code when using the 2nd miscellaneous command. Set an address with A, B or C
that is not used for "#1013 axname" or "#1014 incax".
---Setting range---
A, B, C
【#1171】 taprov Tap return override
Set the tap return override value for the synchronous tapping.
When "0" is set, it will be regarded as 100%.
---Setting range---
0 to 100 (%)
【#1172】 tapovr Tap return override
Set the override value when leaving the tap end point in the synchronous tapping cycle.
When "0" is set, 100 % is applied for the operation.
---Setting range---
0 to 999 (%)
M700VS Series Setup Manual