Appendix 1 Explanation of Parameters
【#3048】 tapt34 Synchronous tap switching time constant 3 (Gear: 11)
Set the time constant to reach the maximum speed (smax1 - 4) with gear 11.
---Setting range---
1 to 5000 (ms)
【#3049】 spt Spindle synchronization acceleration/deceleration time constant
Set the acceleration/deceleration time constant for when the commanded spindle synchronization
speed changes under spindle synchronization control.
---Setting range---
0 to 9999 (ms)
【#3050】 sprlv Spindle synchronization rotation speed attainment level
Set the level of difference between the commanded synchronization spindle speeds and actual
speeds of both the basic and synchronous spindles during spindle synchronization, below which the
spindle speed synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【#3051】 spplv Spindle phase synchronization attainment level
Set the level of phase difference between the basic and synchronous spindles during spindle
synchronization, below which the spindle phase synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【#3052】 spplr Spindle motor spindle relative polarity
Set the spindle motor and spindle's relative polarity.
0: Positive polarity
1: Negative polarity
---Setting range---
0000/0001 (HEX)
【#3053】 sppst Spindle encoder Z -phase position
Set the deviation amount from the spindle's basic point to the spindle detector's Z phase.
Obtain the deviation amount, considering a clockwise direction as positive when viewed from the
spindle's front side.
---Setting range---
0 to 359999 (1/1000°)
【#3054】 sptc1 Spindle synchronization multi-step acceleration/deceleration changeover
speed 1
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant.
---Setting range---
0 to 99999 (r/min)
【#3055】 sptc2 Spindle synchronization multi-step acceleration/deceleration changeover
speed 2
Set the spindle speed for changing the 2nd step's acceleration/deceleration time constant.
---Setting range---
0 to 99999 (r/min)