Appendix 2.11 Network Service Errors (N)

N001 Modem initial error
Details
An error occurred in the modem connection at the power ON.
Remedy
- Check the connection between the NC and modem, connection port and power supply to modem.
N002 Redial over
Details
- The number of redials exceeded due to the dial transmission failure.
Remedy
- Wait a while, and then dial again.
N003 TEL unconnect
Details
- The phone line is not connected.
Remedy
- Check for any disconnection in the modem's phone line.
N004 Net communication error
Details
- An error other than the above occurred during communication.
Remedy
- Note down how the error occurred and contact the service center.
N005 Invalid net communication
Details
- The modem connection port is being used for another function such as input/output.
- The modem connection port settings are incorrect.
Remedy
- Stop using the modem connection port with the other function, and then turn the power ON again.
- Correct the settings of the modem connection port.
N006 Received result of diagnosis
Details
- A diagnosis data file has been received.
Remedy
- Clear the message.
N007 Send data size over
Details
- A file larger than Anshin-net server capacity (64Kbyte) has been transmitted in machining data
sharing.
Remedy
- Reduce the size of machining program file so that it won't exceed the capacity of Anshin-net server.
N008 No file on server
Details
- The file reception failed in machining data sharing because no file exists on Anshin-net server.
Remedy
- Confirm that a machining program file exists on Anshin-net server before receiving it.